<LOGO>
FM Transmitter Measurement Report
Created: 2024-03-04 09-56-39
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 34 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
8 kHz 13 kHz 8227 0,0122
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,77 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 9:56, 4.03.2024
RT
"Pro a proti - Do ceskych kin vstoupil snimek Manzele Stodolov..."
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 13 kHz MIN: 8 kHz % above 77 kHz: 0,0122 Acquired: 2024/03/04 9:56:36 Total samples: 8227 Equivalent time: 0:06:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,4 dBr MIN: -1,4 dBr AVE: -0,77 dBr % above 0,2 dBr: 0,0 Last value: -0,6 dBr (2024/03/04 9:56:35) 09:42 09:44 09:46 09:48 09:50 09:52 09:54 09:56 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality